9B1-GRQ-2-OpGuide-v1-060519.pmdSection Five: InstallationThe Graphi-Q2 should be placed in a well-ventilated, well-grounded equipment rack, preferabl

Página 3 - CE MARKING

105.3. USE WITH A POWERED MIXERWith a powered mixer, the Graphi-Q2 must be inserted between the “Line Out” jack(s) (line level output,before the sign

Página 4 - TABLE OF CONTENTS

11B1-GRQ-2-OpGuide-v1-060519.pmd5.5. SINGLE CHANNEL GRAPHI-Q2: ONE INPUT - TWO OUTPUTSThe single channel Graphi-Q2 also offers a unique setup option,

Página 5 - SECTION ONE: INTRODUCTION

12SECTION SIX: USING GRAPHI-Q2 CONTROLSSection Six: Using Graphi-Q2 Front Panel ControlsMany Graphi-Q2 owners will be immediately familiar with the s

Página 6

13B1-GRQ-2-OpGuide-v1-060519.pmdSECTION SIX: USING GRAPHI-Q2 CONTROLS6.2.2. Linking Channel Controls (Two-channel Units)Two channel Graphi-Q2 units

Página 7

14• An FBX FILTER is essentially an automatically placed, narrowly attenuated parametric filter, withthe center point of its narrow cut tuned to a pre

Página 8

15B1-GRQ-2-OpGuide-v1-060519.pmd6.4.2. Front Panel Control of FBX filtersNote: Most of the front panel and GRQ-Remote control operation of the FBX s

Página 9

16STEP FIVE: SET FIXED FILTERS (Optional)If you want to change the factory default setting of nine Fixed and three Dynamic FBX filters, press and hold

Página 10 - Section Five: Installation

17B1-GRQ-2-OpGuide-v1-060519.pmd6.4.3. Adjustments Available Only with Remote ControlIn addition to FBX, graphic, and high and low cut filters, your G

Página 11 - SECTION FIVE: INSTALLATION

18SECTION SIX: USING GRAPHI-Q2 CONTROLS6.8. FRONT PANEL DEFAULT SETTINGS ADJUSTABLE ONLY BY SOFTWAREGraphi-Q2 models GRQ3121 and GRQ3122 allow adjus

Página 12

1B1-GRQ-2-OpGuide-v1-060519.pmdGRQ3121 (1U, single channel, one input, two outputs)GRQ3122 (2U, dual channel, one input & output per channel)GRQ3

Página 13 - 6.1. FRONT PANEL CALIBRATION

19B1-GRQ-2-OpGuide-v1-060519.pmdSECTION SIX: USING GRAPHI-Q2 CONTROLSSection Seven: GRQ2 Remote Software InstallationThe Graphi-Q2 models GRQ3121 an

Página 14

20SECTION SEVEN: GRQ2 REMOTE SOFTWARE INSTALLATIONYou may connect and control up to eight Graphi-Q2s from one COM port. If your computer offers twoC

Página 15 - Standard on all Sabine

21B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWARESection Eight: Using GRQ2 Remote Software8.1. WELCOME SCREEN/NETWORK CHAIN

Página 16

22or more Graphi-Qs in your serial chain, the following screen (Network Chain) will appear:This screen shows all of the Graphi-Q units connected to yo

Página 17

23B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWAREcut filters by clicking on the slope indicators, located between the two hor

Página 18 - Unity Gain

24MAIN GRQ REMOTE SCREENSECTION EIGHT: USING GRQ2 REMOTE SOFTWARELevel IndicatorsInput, output,compressor gain/reduction, andlimiter indicator forbot

Página 19

25B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.2.5.1. Setting FBX Filters with Graphi-Q Remote SoftwareThe Remote Softwa

Página 20 - 7.2. CONNECTIONS

26for the second channel, or exiting to normal operation.8.2.5.3. Two Cautions When Using Setup Mode1. Do not use turbo during a performance. It is

Página 21 - 7.3. INSTALLING THE SOFTWARE

27B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.2.7. Compressor/Limiter AdjustmentsCompressor/limiter controls are locate

Página 22

28SECTION EIGHT: USING GRQ2 REMOTE SOFTWARECAUTIONFBX / Parametric BypassBe careful when bypassing FBX orParametric filters. This may allowsuppresse

Página 23 - 8.2. GRQ2 MAIN SCREEN

2DECLARATION OF CONFORMITYEN 60065: 1993EN 60742: 1995EN 55103-1: 1997EN 55022: 08:94 + a1:05:05EN 55103-2: 1997EC - DECLARATION OF CONFORMITYCE MARKI

Página 24

29B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.3. LINKING PARAMETERS AND CONTROL WITH THE GRQ-REMOTE SOFT-WAREOne of the

Página 25

30SECTION EIGHT: USING GRQ2 REMOTE SOFTWARERANGE LIMITS If changing cell values within a REL group causes some or all of the linked cell valuesto

Página 26 - GRQ3122-S models

31B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.3.2.5. Compressor Linking Options for GRQ3122 and GRQ3122-S ModelsJust as

Página 27 - When the crossover is

32SECTION EIGHT: USING GRQ2 REMOTE SOFTWAREIf you elect to continue, the value your loaded memory puts into any linked cell on the chosen Graphi-Q 2

Página 28 - You can always right

33B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ REMOTE SOFTWAREcommand execution for a large network of Graphi-Qs for units near the end of

Página 29

34SECTION EIGHT: USING GRQ2 REMOTE SOFTWARE2. Accessing the Stored Pre-sets screen. This will allowup to 20 additional user-speci-fied memory config

Página 30

35B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ REMOTE SOFTWARETHERE IS NOT A BIG DIFFERENCE IN DELAY SETTINGS FROM ONE MEMORY TO THE NEXT.L

Página 31

36SECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.6.2.2. Assigning Contact ClosureChoose ASSIGN CONTACT CLOSURE from the Options Menu, or press key F7.

Página 32

37B2-GRQ-2-OpGuide-v1-060519.pmdSECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.8. PASSWORD PROTECTION WITH GRQ2 REMOTE SOFTWARE8.8.1. Password LevelsTh

Página 33

38SECTION EIGHT: USING GRQ2 REMOTE SOFTWARE8.8.5. Passwords For Multiple Units In a multiple unit serial chain, any PASSWORDS saved will apply to th

Página 34 - 8.4. RESET PARAMETERS

3B1-GRQ-2-OpGuide-v1-060519.pmdTABLE OF CONTENTSSummary of Features ...

Página 35

39B2-GRQ-2-OpGuide-v1-060519.pmdSection Nine: Suggestions for Optimal Use of the Graphi-QLike any powerful tool, the Graphi-Q offers an infinite numb

Página 36

409.2. WIDE & NARROW FILTERS: GRAPHIC, PARAMETRIC, AND FBXHere’s a trick question: how wide are the filters in a 1/3 octave graphic equalizer?The

Página 37

41B2-GRQ-2-OpGuide-v1-060519.pmd9.3. RECOMMENDED EQ USAGE9.3.1. Set the Graphic EQ FirstBecause of the considerations discussed above,Sabine recomm

Página 38

429.4. USING DIGITAL DELAYThis section goes beyond the typical operating guide that only explains the front and back paneladjustments of a piece of e

Página 39

43B2-GRQ-2-OpGuide-v1-060519.pmdSECTION NINE: SUGGESTIONS FOR OPTIMAL USE OF THE GRAPHI-Q29.4.1.3. Center Cluster SpeakersCenter cluster speakers of

Página 40

449.4.2.1. Calculating Comb Filter FrequenciesThe frequencies of the reinforcements and cancellations depend on the delay time (the time differencebe

Página 41

45B2-GRQ-2-OpGuide-v1-060519.pmdSECTION NINE: SUGGESTIONS FOR OPTIMAL USE OF THE GRAPHI-Q2Increasing the loudness more than this, or increasing the d

Página 42 - 9.3. RECOMMENDED EQ USAGE

46SECTION NINE: SUGGESTIONS FOR OPTIMAL USE OF THE GRAPHI-Q2Find a central place in the audience where the center cluster is 6 to 8 dB louder than th

Página 43 - ( )

47B2-GRQ-2-OpGuide-v1-060519.pmdSECTION NINE: SUGGESTIONS FOR OPTIMAL USE OF THE GRAPHI-Q29.5. USING THE COMPRESSOR/LIMITERThe dynamic range (how lo

Página 44

489.5.2. Compressor/Limiter AdjustmentsOutput Output allows you to vary the signal gain after it has been compressed. Withoutthis control, the outpu

Página 45

4Section One: IntroductionCongratulations on your purchase of the Sabine Graphi-Q2. This product represents our latestbreakthrough in our never-endi

Página 46

49B2-GRQ-2-OpGuide-v1-060519.pmdLimit Limit sets an absolute output gain level. Peak input signals rising above thethreshold value set with this para

Página 47 - Delay Figure 6: Synchronizing

50SECTION NINE: SUGGESTIONS FOR OPTIMAL USE OF THE GRAPHI-Q29.5.3. Suggested Compressor SettingsVOCAL COMPRESSION The renowned expressive-ness of

Página 48

51B2-GRQ-2-OpGuide-v1-060519.pmdSection Ten: Troubleshooting TipsIn the unlikely event you should experience trouble with the unit, here are some sug

Página 49 - Output Level Output Level

52Bypass the Graphi-Q. If noise is still there, it’s not the Graphi-Q. If noise goes away, check your gain structure. Make sure theinput level to t

Página 50

53B2-GRQ-2-OpGuide-v1-060519.pmdSection Eleven: Graphi-Q2 Engineering SpecificationsDIGITAL PROCESSING24 bit A/D and D/A32-bit DSPGRAPHIC EQUALIZER31

Página 51

54Warning! This equipment must be earthed.Caution! Risk of electric shock. Do not open.Caution! Shock hazard. Do not remove covers. No user serviceabl

Página 52 - SUGGESTION

55B2-GRQ-2-OpGuide-v1-060519.pmdMADE IN USAManufactured by: Sabine, Inc.13301 NW US Highway 441Alachua, Florida 32615-8544 USAPhone: (386) 418-2000 •

Página 53

56INDEXSymbSymbSymbSymbSymbolsolsolsolsols25-pin connector 19AAAAAAcoustic Image 42, 44, 45Amplifier 26, 35, 40, 50, 9, 10, 15, 16Applications for

Página 55 - Caution!

5B1-GRQ-2-OpGuide-v1-060519.pmdSECTION TWO: ANALOG VS. DIGITAL SIGNAL PROCESSINGSection Two: Analog vs. Digital Signal Processing (DSP)The ongoing d

Página 56 - Limited Warranty

6Section Three: Front & Back Panel ViewsSECTION THREE: FRONT AND BACK PANEL VIEWSClip LED-lightsat 3 dB belowclipping SignalLED-lights wheninput

Página 57

7B1-GRQ-2-OpGuide-v1-060519.pmdSECTION THREE: FRONT AND BACK PANEL VIEWSGGGGGRRRRRQ3Q3Q3Q3Q3122 Front Panel122 Front Panel122 Front Panel122 Front Pa

Página 58

8Section Four: Block Diagram/Internal Signal PathSECTION FOUR: BLOCK DIAGRAM/INTERNAL SIGNAL PATH